        Pool Pump Motors                        

     A.O. Smith Replacement Motors

Hayward NorthStar Pump

Max Rated Single Speed (Round Flange)
    RPM 3450
    Frame 56J

Pump Model
AO Smith
Replacement
HP
Volts
Max Amps
Service Factor
Price

SP4007X10NS USN1102
1
208-230/115
6.0-5.5/11.0 1.4
$219.99
SP4010X15NS USN1152
1-1/2
208-230/115 8.5-7.8/15.6 1.25
$239.99
SP4015X20NS USN1202
2
208-230/115 11.0-10.2/20.4 1.2
$259.99
SP4020X25NS USN1252
2-1/2
208-230
13.0-11.8
1.1
$279.99
SP4025X30NS USN1302
3
208-230
16-14.8
1.2
$359.99

Replacement parts for the NorthStar

Motor Failure:

Shaft seal failure is the major cause of motor failure. This allows moisture to go back to the motor causing corrosion and much more. One of the causes of a shaft seal going bad is the result of the pump running dry which heats up all the parts inside the pump causing damage. It's always best to replace the shaft seal when installing a new motor. If the motor fails due to water damage it can void the manufactures warranty.

All A.O. Smith Motors carry a one year manufacturers warranty (Water damage is not covered)
.
ATTENTION: Improperly wiring a motor will cause irreversible damage. If the motor runs slowly then trips out, it is incorrectly wired. Please carefully read the motor name plate regarding the connections. 115/230 volt motors are shipped from the factory connected for 230 volts. A motor connected for 115 volts that has 230 volts applied will burn up immediately. A motor connected for 230 volts that has 115 volts applied will run slowly and trip out. If the wires moved on the connection board are not replaced on the proper terminals, the result will be a slow running motor that overheats and trips out. These motors have automatic overload protection, which means the motor will not run again until it cools down. If you are experiencing problems, please recheck the connections to insure you have the motor properly wired for the incoming voltage. These motors have been test run at the factory, and they very rarely have problems. Problems are almost always related to improper wiring or other installation issues. Please be sure that you are ordering the correct motor and that follow all installation instructions carefully.





Hayward NothStar Pump



                 

Policies           Shipping          Contact

Discount Pool Zone, LLC
611 Overhill Dr
Brandon, FL 33511
Local 813.689.5800
Toll Free 877.222.6122