| Pool Supplies Home Pool Cleaners Complete Pool Filters Replacement Filters Cartridges & DE Grids Pool Pumps Pool Motors Pool Timers Pool Lights Pool Accessories Pool Test Kits Pool Valves (Multiport) Pool Chlorinators Pool Salt Generator Pool Pump/Skimmer Baskets Chemicals Pool Spa Pool Solar Blankets Parts Pump/Filter Pool Cleaners Pool Vac/Navigator Baracuda Sta-Rite Great White Kreepy Krauly O-Rings |
Important: Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced
Low
Service Factor (Up-Rated)
High Service Factor
Centurion Sq Flange "1081" Up-Rated Low Service Factor
Low Service Factor
High
Service Factor
Centurion
C-Frame "1081" Full-Rated
Motor
Failure:
Shaft seal failure is the major cause of motor failure. This allows moisture to go back to the motor causing corrosion and much more. One of the causes of a shaft seal going bad is the result of the pump running dry which heats up all the parts inside the pump causing damage. It's always best to replace the shaft seal when installing a new motor. If the motor fails due to water damage it can void the manufactures warranty. ATTENTION: Improperly
wiring a motor will
cause irreversible damage. If the motor runs slowly then trips out, it
is incorrectly wired. Please carefully read the motor name plate
regarding the connections. 115/230 volt motors are shipped from the
factory connected for 230 volts. A motor connected for 115 volts that
has 230 volts applied will burn up immediately. A motor connected for
230 volts that has 115 volts applied will run slowly and trip out. If
the wires moved on the connection board are not replaced on the proper
terminals, the result will be a slow running motor that overheats and
trips out. These motors have automatic overload protection, which means
the motor will not run again until it cools down. If you are
experiencing problems, please recheck the connections to insure you
have the motor properly wired for the incoming voltage. These motors
have been test run at the factory, and they very rarely have problems.
Problems are almost always related to improper wiring or other
installation issues. Please be sure that you are ordering the correct
motor and that follow all installation instructions carefully.
|

|
![]() |
![]() |